Résolution Conflit DMP/POWERPATH sur 
su0076
Voir également la doc de Brahim 
jointe
Voici les commandes permettant de 
modifier les tags powerpath en tag ctd 
Ce qui nous a permis ensuite 
d’initialiser les disques avec la commande vxdisksetup –i 
c3t0d54s2
  
vxdmpadm listctlr 
all
[su0076@root:/] vxdmpadm listctlr 
all
CTLR-NAME       
ENCLR-TYPE      STATE      
ENCLR-NAME
=====================================================
c2              
EMC             
ENABLED      EMC0
c3              
EMC             
ENABLED      EMC0
c1   
           Disk            
ENABLED      Disk
c3              
Disk            
ENABLED      Disk
c2              
Disk            
ENABLED      Disk
vxdisk list 
[su0076@root:/] vxdisk 
list
DEVICE       
TYPE            
DISK         
GROUP        
STATUS
c1t0d0s2    
       auto:sliced       
rootdisk     rootdg       
online
c1t1d0s2    
      auto:sliced        
rootmirror   rootdg       
online
emcpower0s2    
auto:cdsdisk    TAM_0993STE_01  
0993STE      online
emcpower1s2    
auto:cdsdisk    0A42APP_02   
0A42APP01    online
emcpower2s2    
auto:cdsdisk    0A42APP_03   
0A42APP01    online
emcpower3s2    
auto:cdsdisk    0A42APP_04   
0A42APP01    online
emcpower4s2    
auto:cdsdisk    0A42APP_01   
0A42APP01    online
c3t0d53s2    
     auto:cdsdisk    
-            
-            
online
c3t0d54s2    
     auto:cdsdisk    
-            
-            
online
c3t0d55s2    
     auto:cdsdisk    
-            
-            
online
commandes permettant de modifier les 
tag powerpath en tag ctd
vxdmpadm setattr enclosure 
EMC0  tpdmode=native
[su0076@root:/] vxdisk 
list
DEVICE       
TYPE            
DISK         
GROUP        
STATUS
c1t0d0s2     
auto:sliced     rootdisk     
rootdg       online
c1t1d0s2     
auto:sliced     rootmirror   
rootdg       online
c2t0d48s2    
auto:cdsdisk    TAM_0993STE_01  
0993STE          
online
c2t0d50s2    
auto:cdsdisk    0A42APP_02   
0A42APP01            
online
c2t0d51s2    
auto:cdsdisk    0A42APP_03   
0A42APP01            
online
c2t0d52s2    
auto:cdsdisk    0A42APP_04   
0A42APP01            
online
c3t0d49s2    
auto:cdsdisk    0A42APP_01   
0A42APP01            
online
c3t0d53s2    
auto:cdsdisk    0A18APP01_01  0A18APP01    
      online
c3t0d54s2    
auto:cdsdisk    c3t0d54      
0A18APP01    
             
online
c3t0d55s2    
auto:cdsdisk    
-            
-               
            
            
online
  
/etc/vx/bin/vxdisksetup 
–i
Il reste à appliquer la procédure du 
support Veritas ci-dessous 
vxddladm excludearray all
mv /etc/vx/array.info 
/etc/vx/array.info.old
mv /etc/vx/disk.info 
/etc/vx/disk.info.old
vxconfigd -k     (this can take some 
time to complete)
vxddladm includearray all
 
Cordialement
 
Mehdi 
Bouthiba
BT Systèmes
Pôle 
serveur
Société Steria - 
Prestataire SFR SI
Nanterre - Rive Défense 
- Bureau BJ106
Tel : (+33) 
(0)1.71.53.20.53